Morley-Ias Fire Alarm Systems |
|
|
We are a leading Supplier of Morley-Ias Fire Alarm Systems such as Morley-Ias Addressable Manual Break Glass Call Point, Morley Intelligent Thermal Detector, Morley-IAS Addressable Audible Warning Devices and Morley-Ias Intelligent Duct Detector Housing from India.
|
|
| Morley-Ias Addressable Manual Break Glass Call Point The MI-MCP-GB is designed to provide a manual alarm interface to the Morley-IAS ZX series intelligent multiprotocol fire alarm control panels. The units are fitted with a built-in monitoring module, which provides an interface to the detection loop. The address of the call point is simply “dialed in” using the rotary switches on the rear of the unit. The call points may be used in most environments as a convenient and quick way of raising an alarm. It is generally installed by exit doors to be operated as people leave a building. For surface mounting a M500KACGB, a matching plastic back box complete with cable terminations is used. If flush mounting is required a single gang, standard electrical knock-out box may be used in conjunction with a terminal tray for cable connection.
Features: - Direct decade addressing (01-99)
- Built-in electronics
- Fast response
- LED shows polling (optional) and activation
- Flush or surface mounting
- Up to 99 per loop (+99 analogue sensors)
- LPCB approved
- Simple to test
- Designed to the requirements of BS5839, Part 2
- IP67 rated model
| 
| Morley Intelligent Thermal Detector The Morley-IAS range of intelligent thermal detectors are used with the ZX series intelligent multi protocol fire alarm control panels to measure thermal levels caused by a fire and report the analogue level of the thermal measurement to the control panel. The use of analogue information provides significant benefits to the end user, installer and serviceman in ways which are not possible with a conventional type system. Since this detector is also addressable, it will help to quickly locate a fire during its early stages. Features: - Dual thermistors
- Rate-of-rise fixed temperature and high fixed temperature models
- Common base for optical, ionisation and thermal sensors
- Addressable-analogue communication
- Stable communication technique with noise immunity
- Low stand-by current
- Rotary decade 01 to 99 address switches
- Remote LED output as standard
- Dual LED design provides 360° viewing angle
- Visible LED’s blink every time the detector is addressed (optional), and illuminate steady on alarm
- Built-in functional test switch activated by external magnet
- Optional relay, isolator, or sounder bases
| 
| Morley-IAS Addressable Audible Warning Devices The Morley-IAS addressable audible warning devices form a co-ordinated range of high quality, high performance products. Designed for use with the ZX series intelligent multi protocol fire alarm control panels, these products feature unique styling, protected electronics, simple tone selection and high efficiency. These products are suitable for most installations. The MI-LABS detector base sounder is particulary suited to hotel bedrooms, allowing the detector and sounder to be installed at the same point. The MI-LABS sounder may also be used as a wall mounted sounder with an optional cover plate. The sounders have been designed to simplify installation and include terminals for both in and out going cables and an earth termination for cable screens. The electronic components in the sounders are protected by a cover to prevent damage during installation. All models are supplied with full instructions Features: - Loop powered
- High sound output
- Low current consumption
- 5 tones available
- Deep or sealed back boxes (wall sounders only)
- Three volume settings as standard
- Available in red or white
- Sounders designed to meet EN54 Part 3
- Rotary DECADE address switches (01-99)
| 
| Morley-Ias Intelligent Duct Detector Housing The DH500 duct housing is designed to sample air currents passing through a duct and allows the early detection of developing fire. The DH500 duct housing will accommodate either the intelligent ionisation sensor or the intelligent optical sensor, either of which provides continuous analogue monitoring of the unit’s sensitivity. When sufficient smoke is sensed, an alarm signal is initiated at the control panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers, change over air handling systems, etc. This can prevent the rapid distribution or isolation of toxic smoke and fire gases throughout the areas served by the duct system.
Special Features Of The Product: - Accommodates intelligent ionization or optical detectors
- Continuous sensitivity monitoring and alarm verification from the panel
- Simple change of detector heads: twist-in, twist-out
- Easy and quick mounting to round or rectangular ducts
- Outputs for remote test station (separate 24 VDC is required)
- Air velocity rating from 150 to 1200 metres per minute (500 to 4,000 feet per minute)
- Clear polycarbonate cover for convenient visual inspection of sampling tube filters
- Rugged Noryl® housing (mounting portion)
- Three year limited warranty
| 
|